Doc inlet temp during regen

Inspect the intake pressure/temperature sensor and

1 12-12-2015, 07:37 AM. cm871 low DOC temp won't reg to clear last code. Prostar ISX CM871 low DOC temp won't regen to clear last code. New turbo. New DOC. Cleaned DPF. Remove EGR and cleaned, no exhaust leaks. Engine temp 200 drg. Fan cycles.- Observe exhaust gas temperatures from DOC Outlet Temp, DOC Inlet Temp and DPF Outlet Temp. - Refer to Aftertreatment Diagnostic Manual Supplement for information regarding OBFCT. 4. If OBFCT runs successfully, go to Step 7. 5. If OBFCT aborts, replay OBFCT using Service Maxx and observe Aftertreatment temperatures and diagnostic trouble codes.

Did you know?

Refer to section "Removal of the EPA07 Temperature Sensors". Verify repair. 5. Monitor the DPF outlet pressure (pin 30) parameter. Is the DPF outlet pressure sensor voltage between 0.44 and 0.56 ... Remove the DOC inlet pressure sensor tube, hose and elbow. Refer to section "Removal of the EPA10 Diesel Oxidation Catalyst Inlet Pressure Sensor ...4. If present, check the condition of the insulation material around the exhaust pipe between the turbocharger and the ATD.. 5. Check the ATD mounting bands for tightness. If needed, tighten the mounting bands on horizon-tally and vertically mounted ATDs to 30 lbf·ft (41 N·m); on step-mounted ATDs, tighten the mount-ing bands to 15 lbf·ft (20 N·m).High DOC outlet temperature for DPF regeneration during the FTP cycle CAT 3126 engine. As seen in the chart, maintaining constant DOC outlet temperature at variable exhaust gas mass flow rate and variable DOC inlet temperature conditions is not a trivial task. Apr 15, 2018 · After it stopped my truck requested another park regen. If you’re needing that many regens, you may need a new filter or perhaps a sensor. You should go see your truck manufacturer. I should add that 200° is normal temp for your dash to show. Mine goes up to about 225° before the fan kicks in and brings it back down to 200°. COOLANT TEMPERATURE: 209F DOC INLET: 432F DPF INLET: 421F DPF OUTLET: 411F Last edited: Jun 10, 2017. 4vmach1, Jun 10, 2017. 4vmach1, Jun 10, 2017 #71 + Quote Reply. Trucking Jobs in 30 seconds. ... During one of the parked regen the delta-p set a out of range on the data monitoring, ...Jan 18, 2020 · Mack MP8 regen issues. 2012 CXU613 with 2012 fault codes so it's not a 2013. Truck arrived at the shop at the beginning of the week. Soot load was level 5. performed a parked regen. DOC inlet temp was bias. DPF outlet temp stayed above inlet temp during regen. 7. Perform a parked regeneration; during the regeneration, monitor (ASL: DOC Inlet Pressure). 8. During the parked regeneration, does either the DOC inlet pressure sensor drop to 0.0 psi at any time? a. Yes; replace the failed sensor. b. No; clear fault and release unit. The code likely occurred after extended idle and soot buildup has cleared ...Jan 18, 2020 · Mack MP8 regen issues. 2012 CXU613 with 2012 fault codes so it's not a 2013. Truck arrived at the shop at the beginning of the week. Soot load was level 5. performed a parked regen. DOC inlet temp was bias. DPF outlet temp stayed above inlet temp during regen. Active regeneration is usually not noticeable to the driver. The vehicle needs to be driven at speeds above 30 mph for approximately 20 to 30 minutes to complete a full regeneration. During regeneration, the exhaust gases reach temperatures above 1,000°F (550°C). Active regeneration is usually not noticeable to the driver. Ash LoadingMar 15, 2020 · The stage1 is before regeneration phase. The DOC inlet temperature, the DPF inlet temperature, and the DPF outlet temperature are sequentially lowered due to the heat loss. The stage2 is during regeneration phase. The DOC inlet temperature slightly reduces due to the vaporization heat of methanol. A) A forced regen will take approximately 40 minutes. It will cycle through 6 stages during this 40 minute period. If the Regen cycle takes longer than this, something else is still wrong. b) During a forced regen cycle, The DOC will get to about 550F, and the doser will activate, first, usually in short intervals, then come on solid.May 22, 2012 · The AFI wont kick in tell the DOC and DPF inlet temps reach 500+*f and the DOC temp must stabilize. Whats the turbo command %, turbo speed, boost pressure, EBP, and engine load during a regen? CAT Factory Trained & Cert. Heavy Equip+Truck Systems. 13. Inspect the DOC inlet pressure sensor electrical connector for corrosion and spread pins. a. If corrosion or damaged (or bent) pins are found, repair as necessary. Verify repairs. b. If no corrosion or damage is found, replace the DOC inlet pressure sensor. Refer to section "Removal of the GHG14 Diesel Oxidation Catalyst Inlet Temperature ...Exhaust Gas Temp 572, DOC Inlet Temp 572, DPF Outlet Gas Temp 1013 and still the REGEN process did not want to finish. The tech cleared my ash level to see if that would work and nothing. I got some recommended solutions, drop and burn the DPF / DOC, sensors, etc..Jan 15, 2017 · During an active regen, engine exhaust temp is slightly higher than normal but not significantly. Maybe 50 to 100 deg. F at best. The high temps are in the exhaust NOX/DPF filter. Everything upstream of that is pretty much normal from my observations. See this video on an entire active regeneration.

Ran an onboard filter cleanliness test to get the regen temps. Soot load was at 44%. Doc intake temp is 775 to 800. Dpf inlet is 1150 to 1185. Dpf outlet is 1220 to 1270. TC1TOP IS 1.5. EGR position is 35%. International is telling me its not eligible for the crankcase filter update, last 8 of vin: EL771725.a. If the DOC inlet pressure starts out above 10 kPa (1.45 psi) and decreases during a parked regen, this indicates that the DPFs were plugged and the parked regen has cleared them. Go to step 8. b. If the DOC inlet pressure starts above the pressure specified below and stays high, the DOC is considered plugged. Go to step 9. Table 1. Emissions ...DPF regeneration temperature rising strategy chiefly considers two temperatures including DOC inlet temperature and the DPF inlet temperature. Temperature rising approaches is based on Great Wall 4D83 diesel engine whose performance parameters are listed in Table 1 and DPF experiment system is shown in Fig. 8. Secondary post injection (Post ...Once the nozzle was cleaned out it would do the regen and the high soot level code went inactive. I'm working on an 08 Western Star with a 60 series Detroit with EGR and DPF. It is a 06R0998711 engine. It has an active 3719 High Soot Level code. The engine runs for about 2 minutes and then shuts down.

After it stopped my truck requested another park regen. If you’re needing that many regens, you may need a new filter or perhaps a sensor. You should go see your truck manufacturer. I should add that 200° is normal temp for your dash to show. Mine goes up to about 225° before the fan kicks in and brings it back down to 200°.There is always something . Excessive idling does cause the DPF to need a regen more often. The Pete I was in, it was recommended that if we had to idle due to temps, that we raise the idle to 1500 to help keep the DPF hot enough to regen itself. However, with the other issues you said it has, sounds like it needs to see Mr. Peterbilt.I began to run NED constantly while driving at work so I can monitor how the engine and regen process look like. Regens usually start at around 60% soot load, the percentage after regeneration goes down into low teens or low single single digits. From what I was able to observe, DOC usually gets somewhere in between 1050° and 1250°…

Reader Q&A - also see RECOMMENDED ARTICLES & FAQs. My unit starts the regen but the DOC inlet temp is o. Possible cause: 3. If all sensors check out okay, perform a Low temp by disconnecting DEF metering uni.

What temp should doc inlet be during regen? Engine rpm should then become stable around 1275 rpm. 13) Monitor DOC inlet temperature. It MUST be greater than 400°C ...NOTE: Normal DOC pressure is less than 10 kPa (1.5 psi) for a 1-Box™ emissions package and 13 kPa (1.9 psi) for a Two-Box option. 38. Using DiagnosticLink, monitor DOC inlet pressure while performing a parked regeneration. Refer to section "Performing a Parked Regeneration Using DiagnosticLink® Standard". Does the DOC inlet pressure start ...Once the DOC is heated up, it can produce high-efficiency oxidization of the post-injected fuel for the DPF regeneration. Based on the DOC light-off temperature achieved, the in-cylinder post fuel injection along with further modulation of the air system parameters can be used to reach a sufficiently high inlet gas temperature for the DPF ...

Good morning Roy, I replace the SCR Outlet Temp Sensor yesterday ran a regen and it went on forever, had to sop it after one hour. The Temps slowly build up, these are the readings after about 1 hour DOC inlet-747 DOC Oultet 1010 DPF Outlet 1092 SCR inlet 1028 SCR Outlet 1045 What do yuo recommend next Still showing same codes SCR NOX ...During regen the temp doesn't get over 305. I thought it had to hit over 500 to kick on injector 7. ... We removed the DPF and DOC and got them baked and blew out. ... Constant regens. Two obd codes. Inlet trap pressure and particulate trap 1 ...May 4, 2021 · Hey Nick, I got a 2014 KW T800 with a paccar mx13. Got some fuel dosing regen issues.VIN: *****Unit will get up to 500 degrees at DOC inlet during regen and begin to dose fuel. DOC outlet … read more

NOTE: Normal DOC pressure is less than 10 kPa (1.5 psi) for a 1-Bo 8. Use DiagnosticLink to start a low temperature regeneration. 9. Wait for 10 minutes, then monitor the Diesel Oxidation Catalyst (DOC) inlet temperature and DOC outlet temperature. Are the readings within 14°C (25°F) of each other? 9.a Yes; stop the low temp regen and Go to step 10. 9.b No; replace the DOC inlet temperature sensor. This guide will assist with diagnosing regen rASL: DOC Inlet Temperature ASL: DOC Outlet Malfunctioning temperature sensors. The temperature sensors, spread through the aftertreatment system, measure the exhaust going into and out of each filter. The first sensor is in the DOC and the last is after the SCR. The sensor’s readings measure how well the system is working, and a faulty sensor can interfere with the regen process. During vehicle operation, active regeneration is performed when I have been working on this bus on and off for several months. It is trying to actively regen around every 2 hours. ISL9. CM2250. engine serial# *****. ECM code CB90010.41. Here are the specs I've gotten while a driving regen is going. DOC Intake Temp - 946.1 f. DPF Intake Temp - 1081.6 f.DOC inlet 500-600F DPF inlet starts to increase once regen starts. DPF outlet will increase after DPF inlet starts building temp and heat transfers through DPF. DPF outlet may peak slightly above inlet temp but should down below the inlet temp. … Was given log file from last completed regen on the truck 10 days ear3251** 2 Diesel Oxidation Catalyst (DOC) Inlet Pressure - The AFI wont kick in tell the DOC and DPF inlet t No; replace the drifted SCR temperature sensor and Go to step 11. Review the parked regen log file. Compare your DOC inlet pressure reading to the screen shots below (steps 12, 13, and 14) to identify a possible cause of the aftertreatment noise. Is the DOC Inlet Pressure starting out high above 10 kPa (1.45 psi) and decreases during a parked ... 2018 volvo vnrRequred regen on dash does not Go awaySent filters out for cleaningInatlled back same thisOn regen doc temp stays at 600, dpf inlet 800 and dpf outler 470Put new 7th injector and 7th injector is spraying at 75 psiDid regen 3 times temps not going up…perform filter reset from texh tool and adaptive reset….after regen 3 times same issue still asking for regen A) A forced regen will take approximately 40 minutes. It will Engine Speed 1100 rpm (1275 rpm during first 12 minutes of regen then 1100 rpm for fuelmap ending in ZGS 999) Turbo Speed 45,000 – 60,000 (turbo is used to create pressure in the DD13 and DD15AT only) Fuel Cut Off Valve 100% (once DOC inlet temp reaches 536° F) Engine Torque Around 5% Actual Torque Load 15 – 18% (greater than 20% may ...If the system doesn't reach this then something is wrong with engine, not the DOC or injector. If the temps reach 525 or better and the inlet temp to the DPF stalls around 800 or is very very slow to reach 1000+ then something is wrong with the injector or DOC. Monitor these parameters during a regen, and you should have these values; Hi Mike. No fault codes, regen starts both fuel pre[... DOC-boosted temp of 1100 deg. , we would have ... There WAS disVocational, Technical or Tra... 5,816 sat - Observe exhaust gas temperatures from DOC Outlet Temp, DOC Inlet Temp and DPF Outlet Temp. - Refer to Aftertreatment Diagnostic Manual Supplement for information regarding OBFCT. 4. If OBFCT runs successfully, go to Step 7. 5. If OBFCT aborts, replay OBFCT using Service Maxx and observe Aftertreatment temperatures and diagnostic trouble codes.During Regen instead of DOC temp staying steady and DFP temps going up, this engine shows DPF outlet temp staying steady while DPF intake and DOC temps keep going up (1000+). I have this truck for 3 years and every forced regen i did was successful and most of the time DPF differential pressure would be zero after the regen.